|
|
Registro Completo |
Biblioteca(s): |
Embrapa Instrumentação. |
Data corrente: |
22/12/1999 |
Data da última atualização: |
09/03/2010 |
Autoria: |
CARVALHO, A. A.; MASCARENHAS, S.; PAULA, M. H. de. |
Afiliação: |
UNESP-Campus de Ilha Solteira; EMBRAPA-CNPDIA. |
Título: |
A new pulsed photoacoustical radiation dosimeter. |
Ano de publicação: |
1988 |
Fonte/Imprenta: |
In: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988. |
Páginas: |
p.II-26. |
Idioma: |
Inglês |
Conteúdo: |
We describe a new method to measure X-rays in its diagnostic region using a new photoacoustical radiation dosimeter. We measure the exposure rate and the energy fluence rate without the necessity to use synchronous detection. The measurement is made determining with a recorder, oscilloscope or electronic peak detector the amplitude of the electrical pulses produced when a chopped X-ray beam strikes a 0,6mm thick Pb detecting sample inside a photoacoustical cell. The pulsed photoacoustical radiation dosimeter (PPARD) consists of an X-ray beam commutator, a photoacoustical cell, a pre-amplifier and an electronic peak detector, oscilloscope or recorder. The PPARD has the following characteristics for diagnostic X-ray beam: 1) it has a linear response with the energy fluence rate; 2) the photoacoustic cell is simple to construct; 3) the instrumentation is inexpensive and easily available; 4) the lower detection limit of energy fluence rate range is 0,42W/m2; 5) the lower detection limit of exposure rate range is 2,0.10E-4 C.KgE-1.sE-1 (0,78 R/s). |
Palavras-Chave: |
Dosimeter; Photoacoustical; Pulsed; Radiation. |
Categoria do assunto: |
-- |
Marc: |
LEADER 01656naa a2200205 a 4500 001 1026546 005 2010-03-09 008 1988 bl --- 0-- u #d 100 1 $aCARVALHO, A. A. 245 $aA new pulsed photoacoustical radiation dosimeter. 260 $c1988 300 $ap.II-26. 520 $aWe describe a new method to measure X-rays in its diagnostic region using a new photoacoustical radiation dosimeter. We measure the exposure rate and the energy fluence rate without the necessity to use synchronous detection. The measurement is made determining with a recorder, oscilloscope or electronic peak detector the amplitude of the electrical pulses produced when a chopped X-ray beam strikes a 0,6mm thick Pb detecting sample inside a photoacoustical cell. The pulsed photoacoustical radiation dosimeter (PPARD) consists of an X-ray beam commutator, a photoacoustical cell, a pre-amplifier and an electronic peak detector, oscilloscope or recorder. The PPARD has the following characteristics for diagnostic X-ray beam: 1) it has a linear response with the energy fluence rate; 2) the photoacoustic cell is simple to construct; 3) the instrumentation is inexpensive and easily available; 4) the lower detection limit of energy fluence rate range is 0,42W/m2; 5) the lower detection limit of exposure rate range is 2,0.10E-4 C.KgE-1.sE-1 (0,78 R/s). 653 $aDosimeter 653 $aPhotoacoustical 653 $aPulsed 653 $aRadiation 700 1 $aMASCARENHAS, S. 700 1 $aPAULA, M. H. de 773 $tIn: INTERNATIONAL SYMPOSIUM ON RADIATION PHYSICS, 4., Oct. 1988, São Paulo, SP. Book of abstracts... São Paulo: [s.n.], 1988.
Download
Esconder MarcMostrar Marc Completo |
Registro original: |
Embrapa Instrumentação (CNPDIA) |
|
Biblioteca |
ID |
Origem |
Tipo/Formato |
Classificação |
Cutter |
Registro |
Volume |
Status |
URL |
Voltar
|
|
Registros recuperados : 2 | |
1. | | MATZEMBACKER, R. G.; PRIMAVESI, A. C. P. de A.; LAJUS, C. A.; BRUNING, G.; OLIVEIRA, J. C.; NORNBERG, J. L.; ROSA, J. L.; ALMEIDA, J. L.; MIRANDA, M.; OLIVEIRA, P. H. de; BASSO, S. M. S. Ensaio nacional de aveias de cobertura de 2003 - análise conjunta. In: REUNIÃO DA COMISSÃO BRASILEIRA DE PESQUISA DE AVEIA, 24., 2004, Pelotas. Resultados experimentais... Pelotas: UFPelotas, 2004. p. 453-460.Tipo: Artigo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
2. | | MATZEMBACKER, R. G.; PRIMAVESI, A. C. P. de A.; LAJUS, C. A.; BRUNING, G.; OLIVEIRA, J. C.; NORNBERG, J. L.; ROSA, J. L.; ALMEIDA, J. L.; MIRANDA, M.; OLIVEIRA, P. H. de; BASSO, S. M. S. Ensaio nacional de aveias forrageiras de 2003 - análise conjunta. In: REUNIÃO DA COMISSÃO BRASILEIRA DE PESQUISA DE AVEIA, 24., 2004, Pelotas. Resultados experimentais... Pelotas: UFPelotas, 2004. p.461-466.Tipo: Artigo em Anais de Congresso |
Biblioteca(s): Embrapa Pecuária Sudeste. |
| |
Registros recuperados : 2 | |
|
Expressão de busca inválida. Verifique!!! |
|
|